Beli Sekarang

Fluke 719 Pro 30g Electric Preasure Calibrator

Rp 000.000
Fluke 719Pro-30G Electric Pressure Calibrator The Fluke 719Pro includes a full functioning loop calibrator that sources, simulates and measures mA signals and more making it the ideal test tool for calibrating high accuracy transmitters, pressure switches and pressure gauges. Get the ultimate in measurement flexibility with the large backlit screen, which displays three parameters at once: Pressure measurement from internal or external sensor Sourced/simulated or measured mA values Temperature measured by optional RTD probe Unique integrated electric pump for one handed pressure calibration Test pressure switches easily with easy-to-use switch test function Precision pressure adjust vernier for easy and accurate pressure calibration Ideal accuracy and performance (0.025 %) for reference class transmitter calibration 30 PSI, 150 PSI and 300 PSI pressure ranges Programmable pressure calibrator pump limit: Eliminates over-pressurization Allows the user to program target pressures for pumping Extended pressure measurement range with any of 29 700Pxx Pressure Modules Pump cleanout ports reduce pump failures from moisture and fluid damage Fluid trap included with the unit to mitigate chance of fluid damage in at-risk applications Precision temperature measurement with optional RTD probe Specifications Pressure Measurement Range -12 to 30 PSI /-0.8 to 2 bar Resolution 0.001 PSI, 0.0001 bar Accuracy (1 year) ± 0.025 % of full scale, 6 months ± 0.035 % of full scale, 1 year Dry Air and non-corrosive gas only Temperature effect (all ranges) Add ± 0.002 % F.S./°C for temps outside of 15 °C to 35 °C No effect on accuracy on all functions from 15 °C to 35 °C Function Range Resolution Accuracy (1 year) Comment mA dc (simulation and measurement) 0-24 mA dc 0.001 mA ± 0.015 % of reading ± 2 counts 1000 ohm maximum load in mA source, 26 V dc maximum voltage in mA simulate Volts dc (measurement only) 30 V dc 0.001 V ± 0.015 % of reading ± 2 counts No AC voltage measurement, do not exceed 30 V dc Temperature (measurement only, Pt100 RTD) -50 to 150 °C (-50 °F to 302 °F) 0.01 °C 0.01 °F Temperature ± 0.1 °C (0.2 °F) ± 0.25 °C (± 0.45 °F) combined uncertainty when using 720 RTD probe (optional accessory) Loop power supply 24 V dc N/A 24 mA at 24 V Temperature effect (all functions) Add ± 0.002 % F.S./°C for temps outside of 15 °C to 35 °C No effect on accuracy on all functions from 15 °C to 35 °C Environmental Operating temperature -10 °C to +50 °C Storage temperature (with batteries) Per battery manufacturer's specification within storage specification below Storage temperature (without batteries) -20 °C to +60 °C Power Requirements Battery Eight (8) standard Alkaline AA batteries Battery life 300 pump cycles to 150 PSI minimum; 1000 pump cycles to 30 PSI; 100 pump cycles to 300 PSI minimum Physical Dimensions (HxWxD) 24.13 cm x 11.18 cm x 7 cm (9.5 in x 4.4 in x 2.8 in) Weight With holster 1.2 kg (2.5 lb) Connections Pressure 1/8 inch female NPT Electrical Standard banana jacks RTD 4 pin miniature circular External module 6 pin miniature circular Engineering Units (Configurable) psi, bar, mbar, kPa, kgcm2, cmH2O@4 °C, cmH2O@20 °C, mH2O@4 °C, mH2O@20 °C, inH2O@4 °C, inH2O@20 °C, inH2O@60 °F, mmHg@0 °C, inHg@0 °C, ftH2O@4 °C, ftH2O@20 °C, ftH2O@60 °F

Produk Terkait Lainnya :

Posting Komentar

 
Kembali Ke Atas