Beli Sekarang

SEW 213HVD ~ 226HVD Contact Detectors

Rp 000
SEW 213 ~ 226 HVD HVD Contact Detectors FEATURES ● Excellent shock resistance. ● Rugged nylon moulding. ● Auto on (when voltage detected). ● Excellent drop resistance. ● Good vibration resistance. ● Loud sound alarm indication. ● Built-in proving and self-test circuit. ● High bright color-coded LEDS. ● Works from standard 9V battery. ● Interchangeable contact electrode. ● Use in all whether conditions. ● Compatible with all link sticks. ● Lightweight, robust & compact. ● Models available from 11kV to 132kV. ● Suitable for indoor and outdoor use. ● Self(auto on) or manual arming. ● Easy access to batteries. ● Customized threshold on demand. ● Auto off (if no voltage detected). ● Waterproof design, protection class : IP65.

SPECIFICATIONS

 PART#
 212HVD
 213HVD
 214HVD
 215HVD
 216HVD
 System Voltage
 4/15kV
 11kV
 33kV
 66kV
 132kV
 Threshold
 Set within
 Range
 1.9kV
 To
 2.1kV
 1.65kV
 To
 4.4kV
 4.95kV
 To
 13.2kV
 11kV
 To
 13kV
 11kV
 To
 13kV
 Response Time
 <1 Sec
 <1 Sec
 <1 Sec
 <1 Sec
 <1 Sec
 Auto-OFF
 3Min
 3Min
 3Min
 3Min
 3Min
 Bridging
 Protection
 YES
 YES
 YES
 YES
 YES
 Spark Protection
 YES
 YES
 YES
 YES
 YES
 Battery Low
 <7V
 <7V
 <7V
 <7V
 <7V
 Threshold
 2.0kV
3.02kV
9.07kV
12kV
12kV
 Battery Current
 <30mA
 <30mA
 <30mA
 <30mA
 <30mA
 Green = Armed
 YES
 YES
 YES
 YES
 YES
 Red = V Detected
 YES
 YES
 YES
 YES
 YES
 Test / Arming Button
 YES
 YES
 YES
 YES
 YES






 PART#
 217HVD
 218HVD
 219HVD
 220HVD
 221HVD
 System Voltage
 11/33kV
44/132kV
66/132kV
6.6/132kV
11/132kV
 Threshold
 Set within
 Range
3.3kV
To
4.95kV
11kV
To
13kV
11kV
To
13kV
2kV
To
3kV
4.4kV
To
6.6kV
 Response Time
 <1 Sec
 <1 Sec
 <1 Sec
 <1 Sec
 <1 Sec
 Auto-OFF
 3Min
 3Min
 3Min
 3Min
 3Min
 Bridging
 Protection
 YES
 YES
 YES
 YES
 YES
 Spark Protection
 YES
 YES
 YES
 YES
 YES
 Battery Low
 <7V
 <7V
 <7V
 <7V
 <7V
 Threshold
4.12kV
12kV
12kV
2.5kV
5kV
 Battery Current
 <30mA
 <30mA
 <30mA
 <30mA
 <30mA
 Green = Armed
 YES
 YES
 YES
 YES
 YES
 Red = V Detected
 YES
 YES
 YES
 YES
 YES
 Test / Arming Button
 YES
 YES
 YES
 YES
 YES






 PART# 222HVD 223HVD 224HVD 225HVD 226HVD
 System Voltage
11/44kV
33/132kV
44kV
kV USER
DEFINED
12/36kV
 Threshold
 Set within
 Range
4.4kV
To
5kV
11kV
To
13kV
6.6kV
To
17.6kV
Xx kV
To
Xx Kv
5.0kV
To
6.0kV
 Response Time
 <1 Sec
 <1 Sec
 <1 Sec
 <1 Sec
 <1 Sec
 Auto-OFF
 3Min
 3Min
 3Min
 3Min
 3Min
 Bridging
 Protection
 YES
 YES
 YES
 YES
 YES
 Spark Protection
 YES
 YES
 YES
 YES
 YES
 Battery Low
 <7V
 <7V
 <7V
 <7V
 <7V
 Threshold
4.75kV
12kV
12kV
User’s Spec
5.4kV
 Battery Current
 <30mA
 <30mA
 <30mA
 <30mA
 <30mA
 Green = Armed
 YES
 YES
 YES
 YES
 YES
 Red = V Detected
 YES
 YES
 YES
 YES
 YES
 Test / Arming Button
 YES
 YES
 YES
 YES
 YES






  

Produk Terkait Lainnya :

Posting Komentar

 
Kembali Ke Atas